Heat recovery ventilation with heat pump

Heat recovery ventilation

Model No: 100L – 500L
Output/Power: 1500W
Height: 5 – 15 Meters
Heat Pump: 90W-230W

Heat recovery ventilation with heat pump

Is a ventilation unit consisting of a counter flow heat exchanger, a heat pump, supply and exhaust air fans, supply air filter, exhaust air filter and controller.
This unit can offer air heating combine with the ventilation system in the house. Fresh air coming from outside can be directly treated by the unit, and polluted indoor air can be exhausted. The heating in polluted indoor air will be recovered by this unit, and return back indoor.

Application for HRV Advanced Ventilation and Air Filtration system:

        Is fully ducted ventilator designed for residential, light commercial, school, child care centers and medical and dental surgeries. It is especially suitable for areas with constant levels of air pollution from vehicle emissions, industrial complexes and coal fired power stations.
Is suitable in ventilation systems where balanced ventilation, heat recovery and warm/cool air is needed. At first the heat will be recovered in the counter flow heat exchanger and then further heat will be supplied to the supply air by the heat pump. During the summer the heat pump can switch to a cooling mode.
Where security is an issue (i.e. windows need to be locked ) and locations with excessive traffic, aircraft or industrial noise, such environments would also benefit from the HRV system.
The filtration system is also effective against mould, pollen and spores that can contribute to asthma. Filters are effective to less than 1 micron.
It will remove stale air from the indoor air space and replace it with fresh air which has been pre-conditioned so as to have minimal impact on the indoor air temperature and humidity.

Features of Heat recovery ventilation with heat pump:

  • compact design
  • reduces heating & cooling loads
  • ventilation, new fresh air, heat recovery design
  • electronic timer – variable settings
  • supply and exhaust duct connection: 200mm diame
  • high static-pressure centrifugal fan, low noise and high reliability
  • (optional) fresh air and exhaust air damper with motor for 200mm duct
Model
KP-30V
Type
Ventilation type
Power supply
V/Ph/Hz
220/50/1
Refrigerant
R410a
Rated heating capacity
kW
3
C.O.P
W/W
2.9
Rated input power
W
1.1
Rated input current
A
4.4
compressor quantity
1
compressor type
rotaty
Airflow direction
Back/Side discharge
Air temperature
5
Airflow
m3/h
400~500
Air pressure
pa
60
Duct dimension
mm
Φ200
Noise level
dB(A)
≤45
Net dimension(L×D×H)
mm
1000×500×640
Packing dimension(L×D×H)
mm
1600×640×72
Net weight
kg
65
Gross weight
kg
76

#Rated heating test conditions: indoor temperature DB/WB 20 ℃ /12 ℃, outdoor outlet air temperature 5 ℃